AI News HubLIVE
站內改寫2 分鐘閱讀

待翻譯:Can You Trust Frozen Hematology Foundation Models under Acquisition Shift?

AI 服務暫時不可用,以下為來源摘要,待恢復後補全翻譯:arXiv:2608.25148v1 Announce Type: new Abstract: Frozen hematology foundation-model (FM) embeddings reach near-saturated in-domain white-blood-cell (WBC) accuracy, but clinical deployment demands reliability across scanners, sites, stains and preparation pipelines. We audit 15 frozen encoders (hematology, pathology, and general vision) across four public single-cell acquisition domains along two axes: accuracy robustness and calibration. In-domain linear-probe macro-F1 is saturated (0.98-0.997), yet cross-dataset macro-F1 drops 34-72% and rankings re-order: DinoBloom-L, the in-domain best, falls to 10th of 15 on the most-shifted target (MLL23) at the benchmark's shared 224-px input, behind RedDino and several general and pathology encoders. Rank transfer is probe-dependent: 1-NN retrieval is more stable on average than a source-fitted linear head (median $\rho$ 0.65 vs 0.45), but neither probe universally predicts target robustness. Calibration also collapses: source-trained probes are nearly calibrated in-domain (expected calibration error, ECE, 0.004) but confidently wrong off-domain (ECE 0.35), and source-fitted temperature scaling transfers poorly. We further audit pretraining exposure and identify MLL23 as DinoBloom's internal cohort; because DinoBloom's only held-out dataset is also our source domain, this benchmark cannot isolate exposure from scanner-associated shift. Label-free adaptation and marginal-entropy-based model selection appear safe under balanced evaluation but fail under realistic WBC class-prior shift. Class-Balanced Re-standardization (CBR), a training-free pseudo-label-balanced feature normalization, improves all evaluated target-prior scenario means and partially improves calibration, although encoder-level exceptions and residual miscalibration remain. Hematology FM benchmarks must therefore jointly audit accuracy, calibration, exposure, and class-prior robustness.

來源arXiv Computer Vision作者: Jai Kumar Sharma, Peeyush Tapadiya

AI 服務暫時不可用,以下為來源正文,待恢復後補全翻譯。

--> [Submitted on 25 Aug 2026] Title:Can You Trust Frozen Hematology Foundation Models under Acquisition Shift? View a PDF of the paper titled Can You Trust Frozen Hematology Foundation Models under Acquisition Shift?, by Jai Kumar Sharma and 1 other authors View PDF HTML (experimental) Abstract:Frozen hematology foundation-model (FM) embeddings reach near-saturated in-domain white-blood-cell (WBC) accuracy, but clinical deployment demands reliability across scanners, sites, stains and preparation pipelines. We audit 15 frozen encoders (hematology, pathology, and general vision) across four public single-cell acquisition domains along two axes: accuracy robustness and calibration. In-domain linear-probe macro-F1 is saturated (0.98-0.997), yet cross-dataset macro-F1 drops 34-72% and rankings re-order: DinoBloom-L, the in-domain best, falls to 10th of 15 on the most-shifted target (MLL23) at the benchmark's shared 224-px input, behind RedDino and several general and pathology encoders. Rank transfer is probe-dependent: 1-NN retrieval is more stable on average than a source-fitted linear head (median $\rho$ 0.65 vs 0.45), but neither probe universally predicts target robustness. Calibration also collapses: source-trained probes are nearly calibrated in-domain (expected calibration error, ECE, 0.004) but confidently wrong off-domain (ECE 0.35), and source-fitted temperature scaling transfers poorly. We further audit pretraining exposure and identify MLL23 as DinoBloom's internal cohort; because DinoBloom's only held-out dataset is also our source domain, this benchmark cannot isolate exposure from scanner-associated shift. Label-free adaptation and marginal-entropy-based model selection appear safe under balanced evaluation but fail under realistic WBC class-prior shift. Class-Balanced Re-standardization (CBR), a training-free pseudo-label-balanced feature normalization, improves all evaluated target-prior scenario means and partially improves calibration, although encoder-level exceptions and residual miscalibration remain. Hematology FM benchmarks must therefore jointly audit accuracy, calibration, exposure, and class-prior robustness. Comments: Accepted at the HemaRAI 2026 workshop (MICCAI 2026 satellite event), oral presentation; to appear in MICCAI 2026 Satellite Events, LNCS, Springer. 25 pages (10 main incl. references + 15 supplementary), 4 figures. Project page: this https URL Subjects: Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI); Quantitative Methods (q-bio.QM) Cite as: arXiv:2608.25148 [cs.CV] (or arXiv:2608.25148v1 [cs.CV] for this version) https://doi.org/10.48550/arXiv.2608.25148 arXiv-issued DOI via DataCite (pending registration) Submission history From: Jai Kumar Sharma [view email] [v1] Tue, 25 Aug 2026 20:55:57 UTC (472 KB) Full-text links: Access Paper: View a PDF of the paper titled Can You Trust Frozen Hematology Foundation Models under Acquisition Shift?, by Jai Kumar Sharma and 1 other authors View PDF HTML (experimental) TeX Source view license Current browse context: cs.CV new | recent | 2026-08 Change to browse by: cs cs.AI q-bio q-bio.QM References & Citations NASA ADS Google Scholar Semantic Scholar Loading... Data provided by: Bibliographic Tools Bibliographic and Citation Tools Bibliographic Explorer Toggle Bibliographic Explorer (What is the Explorer?) Connected Papers Toggle Connected Papers (What is Connected Papers?) Litmaps Toggle Litmaps (What is Litmaps?) scite.ai Toggle scite Smart Citations (What are Smart Citations?) Code, Data, Media Code, Data and Media Associated with this Article alphaXiv Toggle alphaXiv (What is alphaXiv?) Links to Code Toggle CatalyzeX Code Finder for Papers (What is CatalyzeX?) DagsHub Toggle DagsHub (What is DagsHub?) GotitPub Toggle Gotit.pub (What is GotitPub?) Huggingface Toggle Hugging Face (What is Huggingface?) ScienceCast Toggle ScienceCast (What is ScienceCast?) Demos Demos Replicate Toggle Replicate (What is Replicate?) Spaces Toggle Hugging Face Spaces (What is Spaces?) Spaces Toggle TXYZ.AI (What is TXYZ.AI?) Related Papers Recommenders and Search Tools Link to Influence Flower Influence Flower (What are Influence Flowers?) Core recommender toggle CORE Recommender (What is CORE?) Author Venue Institution Topic About arXivLabs arXivLabs: experimental projects with community collaborators arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website. Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them. Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs. Which authors of this paper are endorsers? | Disable MathJax (What is MathJax?)