Robo-MLT: Dual-System Robotic Manipulation for Long-Horizon Medical Laboratory Tasks

Summary

Robo-MLT is a dual-system robotic framework that couples explicit workflow monitoring with learned action generation to improve reliability and recoverability in long-horizon medical laboratory tasks. It achieves 82% and 70% success rates on blood gas analysis and blood sample tube sorting, significantly outperforming baselines, and can replan and continue after human intervention.

SourcearXiv RoboticsAuthor: Zequan Zeng, Kai Wang, Delvin Ce Zhang, Huaping Liu, Zhipeng Yuan, Junqin Yang, YunLong Zhang
Robo-MLT: Dual-System Robotic Manipulation for Long-Horizon Medical Laboratory Tasks
Report an error

The correction channel is not available yet. You can copy the article reference below for later.

Correction instructions
Read article

[Submitted on 9 Nov 2026]

Title:Robo-MLT: Dual-System Robotic Manipulation for Long-Horizon Medical Laboratory Tasks

View a PDF of the paper titled Robo-MLT: Dual-System Robotic Manipulation for Long-Horizon Medical Laboratory Tasks, by Zequan Zeng and 6 other authors

View PDF HTML (experimental)

Abstract:Reliable medical laboratory automation requires robots to complete entire workflows in protocol order while handling changes during execution. A robot may execute each motion correctly yet fail the workflow by confusing visually similar stages or stalling after human intervention. We present Robo-MLT, a dual-system framework that couples explicit workflow monitoring with learned action generation. A vision--language planner composes an ordered atomic-skill sequence from the protocol and the initial workspace observation. A multiframe execution monitor detects when the active skill has completed or become infeasible, then advances the workflow or triggers replanning. A skill-conditioned vision--language--action policy generates the manipulation trajectories, and an asynchronous runtime coordinates it with the monitor. We evaluate Robo-MLT against four policy baselines and a VLM-based monitor baseline on blood gas analysis and blood sample tube sorting, with 50 nominal configurations per method and 20 sample-removal configurations. Robo-MLT achieves task success rates of 82\% and 70\%, exceeding $\pi_{0.5}$ by 30 and 22 percentage points, respectively. After an operator removes the sample being handled, the system revises the remaining plan and continues processing the other samples. These results indicate that, under the evaluated conditions, explicit workflow monitoring makes long-horizon laboratory manipulation more reliable and recoverable.

Comments: 12 pages,7 figures,5 tables,1 algorithm

Subjects:

Robotics (cs.RO)

Cite as: arXiv:2611.13039 [cs.RO]

(or arXiv:2611.13039v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2611.13039

arXiv-issued DOI via DataCite (pending registration)

Submission history

From: Zequan Zeng [view email] [v1] Mon, 9 Nov 2026 11:27:55 UTC (11,587 KB)

Full-text links:

Access Paper:

View a PDF of the paper titled Robo-MLT: Dual-System Robotic Manipulation for Long-Horizon Medical Laboratory Tasks, by Zequan Zeng and 6 other authors

View PDF

HTML (experimental)

TeX Source

view license

Additional Features

Audio Summary

Current browse context:

cs.RO

new | recent | 2026-11

Change to browse by:

cs

References & Citations

SciX

Google Scholar

Semantic Scholar

Loading...

Data provided by:

Bibliographic Tools

Bibliographic and Citation Tools

Bibliographic Explorer Toggle

Bibliographic Explorer (What is the Explorer?)

Connected Papers Toggle

Connected Papers (What is Connected Papers?)

Litmaps Toggle

Litmaps (What is Litmaps?)

scite.ai Toggle

scite Smart Citations (What are Smart Citations?)

Code, Data, Media

Code, Data and Media Associated with this Article

alphaXiv Toggle

alphaXiv (What is alphaXiv?)

Links to Code Toggle

CatalyzeX Code Finder for Papers (What is CatalyzeX?)

DagsHub Toggle

DagsHub (What is DagsHub?)

GotitPub Toggle

Gotit.pub (What is GotitPub?)

Huggingface Toggle

Hugging Face (What is Huggingface?)

ScienceCast Toggle

ScienceCast (What is ScienceCast?)

Demos

Demos

Replicate Toggle

Replicate (What is Replicate?)

Spaces Toggle

Hugging Face Spaces (What is Spaces?)

Spaces Toggle

TXYZ.AI (What is TXYZ.AI?)

Related Papers

Recommenders and Search Tools

Link to Influence Flower

Influence Flower (What are Influence Flowers?)

Core recommender toggle

CORE Recommender (What is CORE?)

Author

Venue

Institution

Topic

About arXivLabs

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Which authors of this paper are endorsers? | Disable MathJax (What is MathJax?)

Key points and analysis

Article intelligence

EngineersAdvanced

Key points

  • Dual-system design: a vision-language planner composes an ordered atomic-skill sequence, while a multiframe execution monitor detects skill completion or infeasibility.
  • Robo-MLT achieves 82% and 70% task success rates on blood gas analysis and blood sample tube sorting, exceeding π0.5 by 30 and 22 percentage points.
  • After an operator removes the sample being handled, the system revises the remaining plan and continues processing other samples, demonstrating recovery capability.
  • An asynchronous runtime coordinates the monitor with a skill-conditioned vision-language-action policy, enabling closed-loop control for long-horizon tasks.

Highlights and analysis are generated automatically and may contain errors. Check the original source.