Skip to content
AI News HubLIVE
Original source2 min read

Ground Reaction Force-Aware Model Predictive Control for Underactuated Upright Physical Assistance

Summary

This paper presents GRF-MPC, a framework that integrates live ground reaction force and center of pressure measurements into a human centroidal dynamics model to optimize assistive forces via real-time quadratic programming. Deployed on the RobUST with an underactuated 4-cable configuration, it outperformed a fully actuated 8-cable baseline, reducing peak CoM error by 19.6%, tracking error by 24.1%, net mechanical work by 28.7%, and increasing voluntary excursion area by 45.9%.

SourcearXiv RoboticsAuthor: Darren Biskup, Jeonghan Yu, Zibo Yu, Sunil K. Agrawal
Ground Reaction Force-Aware Model Predictive Control for Underactuated Upright Physical Assistance
Report an error

The correction channel is not available yet. You can copy the article reference below for later.

Correction instructions
Read article

[Submitted on 9 Nov 2026]

Title:Ground Reaction Force-Aware Model Predictive Control for Underactuated Upright Physical Assistance

View a PDF of the paper titled Ground Reaction Force-Aware Model Predictive Control for Underactuated Upright Physical Assistance, by Darren Biskup and 3 other authors

View PDF HTML (experimental)

Abstract:Many rehabilitation robots execute prescribed motions using reactive tracking controllers that do not explicitly incorporate the user's instantaneous human-ground interaction. This paper presents Ground Reaction Force-Aware Model Predictive Control (GRF-MPC), a framework for upright physical assistance. By integrating live GRF and center of pressure (CoP) measurements directly into a human centroidal dynamics model, GRF-MPC formulates a real-time quadratic program (QP) that optimizes assistive forces and moments over a receding horizon. We deployed GRF-MPC on the Robotic Upright Stand Trainer (RobUST) in an underactuated 4-cable configuration and evaluated it against a fully actuated 8-cable Cartesian impedance baseline in nearly 300 trials across six healthy participants. Across tasks spanning impulsive perturbations, lunge trajectories, and voluntary limits of stability, GRF-MPC reduced peak planar center-of-mass (CoM) error by 19.6% during perturbations, lowered trajectory tracking error by 24.1%, required 28.7% less net mechanical work, and permitted a 45.9% greater normalized voluntary excursion area. The underlying QP solves in under 1 ms, comfortably enabling 100 Hz replanning and demonstrating that incorporating live human-ground interaction into predictive control yields stronger, more transparent physical assistance with half the actuators.

Comments: Accepted for publication in IEEE Robotics and Automation Letters (RA-L), October 2026. 8 pages, 5 figures

Subjects:

Robotics (cs.RO); Systems and Control (eess.SY)

Cite as: arXiv:2611.13204 [cs.RO]

(or arXiv:2611.13204v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2611.13204

arXiv-issued DOI via DataCite (pending registration)

Related DOI:

https://doi.org/10.1109/LRA.2026.3752000

DOI(s) linking to related resources

Submission history

From: Darren Biskup [view email] [v1] Mon, 9 Nov 2026 20:29:14 UTC (14,761 KB)

Full-text links:

Access Paper:

View a PDF of the paper titled Ground Reaction Force-Aware Model Predictive Control for Underactuated Upright Physical Assistance, by Darren Biskup and 3 other authors

View PDF

HTML (experimental)

TeX Source

view license

Additional Features

Audio Summary

Current browse context:

cs.RO

new | recent | 2026-11

Change to browse by:

cs cs.SY eess eess.SY

References & Citations

SciX

Google Scholar

Semantic Scholar

Loading...

Data provided by:

Bibliographic Tools

Bibliographic and Citation Tools

Bibliographic Explorer Toggle

Bibliographic Explorer (What is the Explorer?)

Connected Papers Toggle

Connected Papers (What is Connected Papers?)

Litmaps Toggle

Litmaps (What is Litmaps?)

scite.ai Toggle

scite Smart Citations (What are Smart Citations?)

Code, Data, Media

Code, Data and Media Associated with this Article

alphaXiv Toggle

alphaXiv (What is alphaXiv?)

Links to Code Toggle

CatalyzeX Code Finder for Papers (What is CatalyzeX?)

DagsHub Toggle

DagsHub (What is DagsHub?)

GotitPub Toggle

Gotit.pub (What is GotitPub?)

Huggingface Toggle

Hugging Face (What is Huggingface?)

ScienceCast Toggle

ScienceCast (What is ScienceCast?)

Demos

Demos

Replicate Toggle

Replicate (What is Replicate?)

Spaces Toggle

Hugging Face Spaces (What is Spaces?)

Spaces Toggle

TXYZ.AI (What is TXYZ.AI?)

Related Papers

Recommenders and Search Tools

Link to Influence Flower

Influence Flower (What are Influence Flowers?)

Core recommender toggle

CORE Recommender (What is CORE?)

Author

Venue

Institution

Topic

About arXivLabs

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Which authors of this paper are endorsers? | Disable MathJax (What is MathJax?)

Key points and analysis

Article intelligence

EngineersAdvanced

Key points

  • GRF-MPC incorporates live GRF and CoP measurements directly into a human centroidal dynamics model, formulating a real-time QP for assistive force optimization.
  • On the RobUST with an underactuated 4-cable setup, GRF-MPC outperformed a fully actuated 8-cable Cartesian impedance baseline across perturbations, lunge trajectories, and voluntary stability limits.
  • Improvements include 19.6% lower peak planar CoM error, 24.1% lower tracking error, 28.7% less net mechanical work, and 45.9% greater normalized voluntary excursion area.
  • The underlying QP solves in under 1 ms, enabling 100 Hz replanning and demonstrating stronger, more transparent assistance with half the actuators.

Highlights and analysis are generated automatically and may contain errors. Check the original source.