Skip to content
AI News HubLIVE
Original source2 min read

Uncovering the Blind Spots of OKS-mAP: A Unified Protocol for Occlusion, Joint-Angle, and Temporal Evaluation of 2D Pose Estimators

Summary

The paper identifies three blind spots in OKS-mAP, the dominant metric for 2D human pose estimation: it does not distinguish visible from occluded keypoints, does not measure joint-angle error, and ignores temporal stability of tracking-free per-frame inference. The authors propose a three-module supplementary protocol and evaluate it on four datasets and four models, finding that aggregate mAP overestimates occluded-scene performance in every combination and that angle and temporal metrics provide independent information.

SourcearXiv Computer VisionAuthor: Yifan Fan
Uncovering the Blind Spots of OKS-mAP: A Unified Protocol for Occlusion, Joint-Angle, and Temporal Evaluation of 2D Pose Estimators
Report an error

The correction channel is not available yet. You can copy the article reference below for later.

Correction instructions
Read article

[Submitted on 22 Oct 2026]

Title:Uncovering the Blind Spots of OKS-mAP: A Unified Protocol for Occlusion, Joint-Angle, and Temporal Evaluation of 2D Pose Estimators

View a PDF of the paper titled Uncovering the Blind Spots of OKS-mAP: A Unified Protocol for Occlusion, Joint-Angle, and Temporal Evaluation of 2D Pose Estimators, by Yifan Fan

View PDF HTML (experimental)

Abstract:The dominant metric for 2D human pose estimation, OKS-mAP, has three blind spots: it does not distinguish visible from occluded keypoints, does not measure joint-angle error, and is silent on the temporal stability of tracking-free per-frame inference. We propose a supplementary protocol with three modules: (M1) OKS-mAP stratified by ground-truth visibility, with Delta_occ = mAP(v=1) - mAP(full), quantifying how much the aggregate metric masks occlusion-specific differences; (M2) joint-angle error (RMSE/MAE/P95) plus knee-valgus detection consistency; (M3) frame-to-frame displacement, median-filter residual jitter, and jump rate, before and after OneEuro smoothing. We ran it on four datasets (COCO val2017, CrowdPose, OCHuman, PoseTrack18) and four models from two architecture families (YOLO11s-pose, an occlusion-domain fine-tuned variant, ViTPose-B/L), under a common detector-free oracle protocol and an open-source harness. Delta_occ is negative in every combination (-0.19 to -0.47): aggregate mAP overestimates occluded-scene performance in every tested combination. Joint-angle error is amplified in occluded layers; angle metrics reveal differences mAP cannot localize, e.g., the smaller occlusion-trained model significantly outperforming a larger transformer in occluded elbows. On PoseTrack18 val, raw jitter matched between the two YOLO models; pixel-domain OneEuro smoothing cut jump rates 9-10% at no matched-scope AP cost; residual jitter persists after detector removal; the transformer pair's jump rate is significantly lower; smoothing benefits replicate across architectures. Stratified mAP tracks full mAP closely (sign-consistency 1.0, 12/12), serving magnitude diagnosis rather than re-ranking; angle-metric difference vectors (especially knee) partially diverge, suggesting independent information. The protocol and harness are open-sourced, complementing rather than replacing OKS-mAP.

Comments: 15 pages, 7 figures

Subjects:

Computer Vision and Pattern Recognition (cs.CV)

Cite as: arXiv:2611.12911 [cs.CV]

(or arXiv:2611.12911v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2611.12911

arXiv-issued DOI via DataCite

Submission history

From: Yifan Fan [view email] [v1] Thu, 22 Oct 2026 11:17:52 UTC (690 KB)

Full-text links:

Access Paper:

View a PDF of the paper titled Uncovering the Blind Spots of OKS-mAP: A Unified Protocol for Occlusion, Joint-Angle, and Temporal Evaluation of 2D Pose Estimators, by Yifan Fan

View PDF

HTML (experimental)

TeX Source

view license

Additional Features

Audio Summary

Current browse context:

cs.CV

new | recent | 2026-11

Change to browse by:

cs

References & Citations

SciX

Google Scholar

Semantic Scholar

Loading...

Data provided by:

Bibliographic Tools

Bibliographic and Citation Tools

Bibliographic Explorer Toggle

Bibliographic Explorer (What is the Explorer?)

Connected Papers Toggle

Connected Papers (What is Connected Papers?)

Litmaps Toggle

Litmaps (What is Litmaps?)

scite.ai Toggle

scite Smart Citations (What are Smart Citations?)

Code, Data, Media

Code, Data and Media Associated with this Article

alphaXiv Toggle

alphaXiv (What is alphaXiv?)

Links to Code Toggle

CatalyzeX Code Finder for Papers (What is CatalyzeX?)

DagsHub Toggle

DagsHub (What is DagsHub?)

GotitPub Toggle

Gotit.pub (What is GotitPub?)

Huggingface Toggle

Hugging Face (What is Huggingface?)

ScienceCast Toggle

ScienceCast (What is ScienceCast?)

Demos

Demos

Replicate Toggle

Replicate (What is Replicate?)

Spaces Toggle

Hugging Face Spaces (What is Spaces?)

Spaces Toggle

TXYZ.AI (What is TXYZ.AI?)

Related Papers

Recommenders and Search Tools

Link to Influence Flower

Influence Flower (What are Influence Flowers?)

Core recommender toggle

CORE Recommender (What is CORE?)

Author

Venue

Institution

Topic

About arXivLabs

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Which authors of this paper are endorsers? | Disable MathJax (What is MathJax?)

Key points and analysis

Article intelligence

InvestorsAdvanced

Key points

  • OKS-mAP has three blind spots: occlusion, joint angle, and temporal stability
  • Delta_occ is negative in all combinations (-0.19 to -0.47), showing aggregate mAP overestimates occluded performance
  • OneEuro smoothing cuts jump rates by 9-10% with no matched-scope AP cost
  • Stratified mAP tracks full mAP closely (sign-consistency 1.0), serving magnitude diagnosis rather than re-ranking

Highlights and analysis are generated automatically and may contain errors. Check the original source.