Skip to content
AI News HubLIVE
Original source2 min read

Selective Surgical Action-Center Localization: Retaining Localization Gains through Supervised Scoring

Summary

The paper proposes a selective localization pipeline that combines heatmap and coordinate supervision with a logistic-regression scorer for surgical action-center localization. On 5,000 frames from 50 surgical sources, at an 80% acceptance quota and a tolerance of 0.10 times the image diagonal, the method retains 46.08 correct outputs per 100 inputs versus 44.20 for the baseline, a gain of 1.88. The work argues that evaluating retained correct outputs, not just the supply of correct predictions, is necessary to tell whether a selection rule preserves or erodes localization improvements.

SourcearXiv Computer VisionAuthor: Yanchong Xue, Wanting Zhang, Lingtao Yu, Guochao Zhang
Selective Surgical Action-Center Localization: Retaining Localization Gains through Supervised Scoring
Report an error

The correction channel is not available yet. You can copy the article reference below for later.

Correction instructions
Read article

[Submitted on 8 Nov 2026]

Title:Selective Surgical Action-Center Localization:Retaining Localization Gains through Supervised Scoring

View a PDF of the paper titled Selective Surgical Action-Center Localization:Retaining Localization Gains through Supervised Scoring, by Yanchong Xue and 3 other authors

View PDF HTML (experimental)

Abstract:Surgical action-center localization requires both an accurate reference point and a decision about whether to report it. When frames with and without a reportable center are mixed, the benefit of improved localization depends on which correct candidates survive selection. We present a selective localization pipeline combining heatmap and coordinate supervision with a logistic-regression scorer. The scorer learns to identify predictions with a reportable center and a localization error within a specified tolerance. The internal evaluation uses 5,000 frames from 50 surgical sources, five source-grouped folds and two random seeds. Matched locator and scoring comparisons track correct candidates and their rejection. At an 80% acceptance quota per source and a tolerance of 0.10 times the image diagonal, our method retains 46.08 correct outputs per 100 inputs. The baseline locator with the same scoring approach retains 44.20. The gain is 1.88 (descriptive 95% source-paired bootstrap interval, 0.94 to 2.79). Under entropy-based selection, increased rejection of correct predictions offsets the higher supply of correct predictions on average. For the coordinate-supervised locator, supervised scoring reduces these rejections from 6.15 to 2.99 per 100 inputs. Evaluating retained correct outputs reveals whether a selection rule preserves or erodes an improvement in localization.

Subjects:

Computer Vision and Pattern Recognition (cs.CV)

Cite as: arXiv:2611.12977 [cs.CV]

(or arXiv:2611.12977v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2611.12977

arXiv-issued DOI via DataCite (pending registration)

Submission history

From: Xue Yanchong [view email] [v1] Sun, 8 Nov 2026 04:58:41 UTC (29,249 KB)

Full-text links:

Access Paper:

View a PDF of the paper titled Selective Surgical Action-Center Localization:Retaining Localization Gains through Supervised Scoring, by Yanchong Xue and 3 other authors

View PDF

HTML (experimental)

TeX Source

view license

Additional Features

Audio Summary

Current browse context:

cs.CV

new | recent | 2026-11

Change to browse by:

cs

References & Citations

SciX

Google Scholar

Semantic Scholar

Loading...

Data provided by:

Bibliographic Tools

Bibliographic and Citation Tools

Bibliographic Explorer Toggle

Bibliographic Explorer (What is the Explorer?)

Connected Papers Toggle

Connected Papers (What is Connected Papers?)

Litmaps Toggle

Litmaps (What is Litmaps?)

scite.ai Toggle

scite Smart Citations (What are Smart Citations?)

Code, Data, Media

Code, Data and Media Associated with this Article

alphaXiv Toggle

alphaXiv (What is alphaXiv?)

Links to Code Toggle

CatalyzeX Code Finder for Papers (What is CatalyzeX?)

DagsHub Toggle

DagsHub (What is DagsHub?)

GotitPub Toggle

Gotit.pub (What is GotitPub?)

Huggingface Toggle

Hugging Face (What is Huggingface?)

ScienceCast Toggle

ScienceCast (What is ScienceCast?)

Demos

Demos

Replicate Toggle

Replicate (What is Replicate?)

Spaces Toggle

Hugging Face Spaces (What is Spaces?)

Spaces Toggle

TXYZ.AI (What is TXYZ.AI?)

Related Papers

Recommenders and Search Tools

Link to Influence Flower

Influence Flower (What are Influence Flowers?)

Core recommender toggle

CORE Recommender (What is CORE?)

Author

Venue

Institution

Topic

About arXivLabs

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Which authors of this paper are endorsers? | Disable MathJax (What is MathJax?)

Key points and analysis

Article intelligence

InvestorsAdvanced

Key points

  • Combines heatmap and coordinate supervision with a logistic-regression scorer that identifies reportable centers within a tolerance.
  • Retains 46.08 correct outputs per 100 inputs at 80% acceptance quota and 0.10 diagonal tolerance, versus 44.20 for the baseline, a gain of 1.88 (95% source-paired bootstrap interval 0.94–2.79).
  • Entropy-based selection can offset localization gains because more correct predictions are rejected; supervised scoring cuts rejections of correct predictions from 6.15 to 2.99 per 100 inputs for the coordinate-supervised locator.
  • Evaluation should focus on retained correct outputs to determine whether a selection rule preserves or erodes localization improvements.

Highlights and analysis are generated automatically and may contain errors. Check the original source.