Skip to content
AI News HubLIVE
Source content · Analysis pending2 min read

Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

Summary

arXiv:2609.19230v1 Announce Type: new Abstract: Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines a…

SourcearXiv Computer VisionAuthor: Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar, Rao Muhammad Anwer, Shadab Khan
Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings
Report an error

The correction channel is not available yet. You can copy the article reference below for later.

Correction instructions
Read article

[Submitted on 16 Sep 2026]

Title:Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

View a PDF of the paper titled Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings, by Chao Qin and 6 other authors

View PDF HTML (experimental)

Abstract:Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code.

Comments: The PDF includes the Supplementary Information

Subjects:

Computer Vision and Pattern Recognition (cs.CV)

Cite as: arXiv:2609.19230 [cs.CV]

(or arXiv:2609.19230v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2609.19230

arXiv-issued DOI via DataCite (pending registration)

Submission history

From: Chao Qin [view email] [v1] Wed, 16 Sep 2026 15:34:21 UTC (3,842 KB)

Full-text links:

Access Paper:

View a PDF of the paper titled Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings, by Chao Qin and 6 other authors

View PDF

HTML (experimental)

TeX Source

view license

Current browse context:

cs.CV

new | recent | 2026-09

Change to browse by:

cs

References & Citations

NASA ADS

Google Scholar

Semantic Scholar

Loading...

Data provided by:

Bibliographic Tools

Bibliographic and Citation Tools

Bibliographic Explorer Toggle

Bibliographic Explorer (What is the Explorer?)

Connected Papers Toggle

Connected Papers (What is Connected Papers?)

Litmaps Toggle

Litmaps (What is Litmaps?)

scite.ai Toggle

scite Smart Citations (What are Smart Citations?)

Code, Data, Media

Code, Data and Media Associated with this Article

alphaXiv Toggle

alphaXiv (What is alphaXiv?)

Links to Code Toggle

CatalyzeX Code Finder for Papers (What is CatalyzeX?)

DagsHub Toggle

DagsHub (What is DagsHub?)

GotitPub Toggle

Gotit.pub (What is GotitPub?)

Huggingface Toggle

Hugging Face (What is Huggingface?)

ScienceCast Toggle

ScienceCast (What is ScienceCast?)

Demos

Demos

Replicate Toggle

Replicate (What is Replicate?)

Spaces Toggle

Hugging Face Spaces (What is Spaces?)

Spaces Toggle

TXYZ.AI (What is TXYZ.AI?)

Related Papers

Recommenders and Search Tools

Link to Influence Flower

Influence Flower (What are Influence Flowers?)

Core recommender toggle

CORE Recommender (What is CORE?)

Author

Venue

Institution

Topic

About arXivLabs

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Which authors of this paper are endorsers? | Disable MathJax (What is MathJax?)

Key points and analysis

Article intelligence

InvestorsAdvanced

Key points

  • AI generation is temporarily unavailable; this entry was preserved with deterministic fallback metadata.
  • arXiv:2609.19230v1 Announce Type: new Abstract: Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task model…

Highlights and analysis are generated automatically and may contain errors. Check the original source.