Skip to content
AI News HubLIVE
Original source2 min read

mmTherm: Absolute 3D Human Pose Estimation from Low-Resolution Thermal Images and mmWave Radar

Summary

mmTherm introduces a lightweight framework that explicitly combines body structure and joint direction cues from low-resolution thermal imaging with range measurements from mmWave radar for absolute 3D human pose estimation. On OctoNet, it reduces cross-user absolute joint error by 33% and root localization error by 38% while requiring substantially fewer parameters and less inference computation.

SourcearXiv Computer VisionAuthor: Zhaoxin Chang, Badii Jouaber, Daqing Zhang
mmTherm: Absolute 3D Human Pose Estimation from Low-Resolution Thermal Images and mmWave Radar
Report an error

The correction channel is not available yet. You can copy the article reference below for later.

Correction instructions
Read article

[Submitted on 17 Nov 2026]

Title:mmTherm: Absolute 3D Human Pose Estimation from Low-Resolution Thermal Images and mmWave Radar

View a PDF of the paper titled mmTherm: Absolute 3D Human Pose Estimation from Low-Resolution Thermal Images and mmWave Radar, by Zhaoxin Chang and 2 other authors

View PDF HTML (experimental)

Abstract:Absolute 3D human pose estimation (HPE) aims to recover both a person's body pose and their global position in 3D space. Privacy-preserving millimeter-wave (mmWave) radar provides distance and direction measurement capabilities, but its sparse point clouds make HPE under-constrained. Low-resolution thermal imaging can provide complementary observations of body direction and structure. However, our evaluation shows that a strong feature-level fusion baseline loses much of its localization and HPE advantage when generalizing to unseen subjects, with radial localization becoming less accurate than a radar-only baseline. Motivated by this finding, we introduce mmTherm, a lightweight framework that explicitly incorporates the complementary geometric properties of thermal imaging and mmWave radar. It combines body structure and joint directions estimated from thermal images with range information from radar to localize the body and reconstruct its 3D pose. Experiments on OctoNet show that mmTherm reduces cross-user absolute joint error by 33% and root localization error by 38% relative to the strongest corresponding baselines, while requiring substantially fewer parameters and less computation at inference.

Subjects:

Computer Vision and Pattern Recognition (cs.CV)

Cite as: arXiv:2611.23477 [cs.CV]

(or arXiv:2611.23477v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2611.23477

arXiv-issued DOI via DataCite (pending registration)

Submission history

From: Zhaoxin Chang [view email] [v1] Tue, 17 Nov 2026 20:30:24 UTC (485 KB)

Full-text links:

Access Paper:

View a PDF of the paper titled mmTherm: Absolute 3D Human Pose Estimation from Low-Resolution Thermal Images and mmWave Radar, by Zhaoxin Chang and 2 other authors

View PDF

HTML (experimental)

TeX Source

view license

Additional Features

Audio Summary

Current browse context:

cs.CV

new | recent | 2026-11

Change to browse by:

cs

References & Citations

SciX

Google Scholar

Semantic Scholar

Loading...

Data provided by:

Bibliographic Tools

Bibliographic and Citation Tools

Bibliographic Explorer Toggle

Bibliographic Explorer (What is the Explorer?)

Connected Papers Toggle

Connected Papers (What is Connected Papers?)

Litmaps Toggle

Litmaps (What is Litmaps?)

scite.ai Toggle

scite Smart Citations (What are Smart Citations?)

Code, Data, Media

Code, Data and Media Associated with this Article

alphaXiv Toggle

alphaXiv (What is alphaXiv?)

Links to Code Toggle

CatalyzeX Code Finder for Papers (What is CatalyzeX?)

DagsHub Toggle

DagsHub (What is DagsHub?)

GotitPub Toggle

Gotit.pub (What is GotitPub?)

Huggingface Toggle

Hugging Face (What is Huggingface?)

ScienceCast Toggle

ScienceCast (What is ScienceCast?)

Demos

Demos

Replicate Toggle

Replicate (What is Replicate?)

Spaces Toggle

Hugging Face Spaces (What is Spaces?)

Spaces Toggle

TXYZ.AI (What is TXYZ.AI?)

Related Papers

Recommenders and Search Tools

Link to Influence Flower

Influence Flower (What are Influence Flowers?)

Core recommender toggle

CORE Recommender (What is CORE?)

Author

Venue

Institution

Topic

About arXivLabs

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Which authors of this paper are endorsers? | Disable MathJax (What is MathJax?)

Key points and analysis

Article intelligence

InvestorsAdvanced

Key points

  • mmTherm fuses complementary geometric properties of thermal imaging and mmWave radar for absolute 3D HPE
  • It reduces cross-user absolute joint error by 33% and root localization error by 38% on OctoNet
  • It achieves these gains with significantly fewer parameters and less computation at inference than strong baselines

Highlights and analysis are generated automatically and may contain errors. Check the original source.