Skip to content
AI News HubLIVE
Original source3 min read

LuxTac: A Flexible, Scalable, and Open-Source Optical Taxel Array with Distributed Three-Axis Force Sensing for Tactile Robot Learning

Summary

LuxTac is a 3.5 mm thick optical taxel array built from off-the-shelf parts that, to the authors' knowledge, is the first to resolve shear at individual taxels. Normal sensing is linear (R² = 0.999) from 104 mN to at least 5.8 N, and three-axis force estimates achieve summed R² of 0.92–0.96. Adding LuxTac pressure readings to an Action Chunking Transformer policy substantially improves peg-in-hole success over a vision-only baseline.

SourcearXiv RoboticsAuthor: Md Rakibul Islam Prince, John Pelan, Zhiyuan Zhang, Adyaa Khera, Katherine Pesetski, Adeesh Desai, Akimizu Sugiyama, Minwoo Ki, Benjamin Alan Capelle, Temitope Ibrahim Amosa, Zijie Xu, Yihan Huang, Taehun Chung, Long Wang, Wei Li, Shaoting Lin, Yu She
LuxTac: A Flexible, Scalable, and Open-Source Optical Taxel Array with Distributed Three-Axis Force Sensing for Tactile Robot Learning
Report an error

The correction channel is not available yet. You can copy the article reference below for later.

Correction instructions
Read article

[Submitted on 17 Nov 2026]

Title:LuxTac: A Flexible, Scalable, and Open-Source Optical Taxel Array with Distributed Three-Axis Force Sensing for Tactile Robot Learning

View a PDF of the paper titled LuxTac: A Flexible, Scalable, and Open-Source Optical Taxel Array with Distributed Three-Axis Force Sensing for Tactile Robot Learning, by Md Rakibul Islam Prince and 16 other authors

View PDF HTML (experimental)

Abstract:Low-cost tactile arrays have made touch a practical input for robot learning, but piezoresistive designs sense only pressure, while camera-based sensors that also resolve shear are too bulky to tile over a gripper. To solve this problem, we present LuxTac, a flexible, scalable optical taxel array, about 3.5 mm thick and built from off-the-shelf parts. Each taxel is a digital RGBC light-to-digital converter under a translucent white silicone layer capped by an opaque black film, so the back-scattered LED light falls monotonically with local indentation depth. The same board accepts two interchangeable gel cartridges: a plain one for normal sensing, and one with colored walls that encodes the local shear in the color of the returned light, with no camera, magnets, or bump overlay, making LuxTac, to our knowledge, the first optical taxel array to resolve shear at individual taxels. Characterized with an automated CNC indenter and a six-axis force/torque sensor, the normal cartridge responds linearly to force ($R^2$ = 0.999) from 104 mN to at least 5.8 N, with 2.0% repeatability, 5.9% hysteresis, and a taxel-to-taxel variation of 6-10% after normalization. With the shear cartridge, per-taxel models estimate the three-axis force at every taxel; across three indenter shapes and nine held-out sessions, the summed estimates reach $R^2$ = 0.96/0.96/0.92 in x/y/z, each taxel's estimate 0.92/0.93/0.94, and the median shear-direction error is 4.8 degrees. Adding LuxTac pressure readings to an Action Chunking Transformer policy substantially improves peg-in-hole success over a vision-only baseline. Design files, code, and videos are available at this https URL.

Comments: 11 pages, 9 figures, 5 tables. Project page: this https URL

Subjects:

Robotics (cs.RO)

Cite as: arXiv:2611.23575 [cs.RO]

(or arXiv:2611.23575v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2611.23575

arXiv-issued DOI via DataCite (pending registration)

Submission history

From: Md Rakibul Islam Prince [view email] [v1] Tue, 17 Nov 2026 22:21:50 UTC (11,843 KB)

Full-text links:

Access Paper:

View a PDF of the paper titled LuxTac: A Flexible, Scalable, and Open-Source Optical Taxel Array with Distributed Three-Axis Force Sensing for Tactile Robot Learning, by Md Rakibul Islam Prince and 16 other authors

View PDF

HTML (experimental)

TeX Source

view license

Additional Features

Audio Summary

Current browse context:

cs.RO

new | recent | 2026-11

Change to browse by:

cs

References & Citations

SciX

Google Scholar

Semantic Scholar

Loading...

Data provided by:

Bibliographic Tools

Bibliographic and Citation Tools

Bibliographic Explorer Toggle

Bibliographic Explorer (What is the Explorer?)

Connected Papers Toggle

Connected Papers (What is Connected Papers?)

Litmaps Toggle

Litmaps (What is Litmaps?)

scite.ai Toggle

scite Smart Citations (What are Smart Citations?)

Code, Data, Media

Code, Data and Media Associated with this Article

alphaXiv Toggle

alphaXiv (What is alphaXiv?)

Links to Code Toggle

CatalyzeX Code Finder for Papers (What is CatalyzeX?)

DagsHub Toggle

DagsHub (What is DagsHub?)

GotitPub Toggle

Gotit.pub (What is GotitPub?)

Huggingface Toggle

Hugging Face (What is Huggingface?)

ScienceCast Toggle

ScienceCast (What is ScienceCast?)

Demos

Demos

Replicate Toggle

Replicate (What is Replicate?)

Spaces Toggle

Hugging Face Spaces (What is Spaces?)

Spaces Toggle

TXYZ.AI (What is TXYZ.AI?)

Related Papers

Recommenders and Search Tools

Link to Influence Flower

Influence Flower (What are Influence Flowers?)

Core recommender toggle

CORE Recommender (What is CORE?)

Author

Venue

Institution

Topic

About arXivLabs

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Which authors of this paper are endorsers? | Disable MathJax (What is MathJax?)

Key points and analysis

Article intelligence

EngineersAdvanced

Key points

  • About 3.5 mm thick, uses digital RGBC light-to-digital converters and interchangeable silicone gel cartridges to achieve per-taxel three-axis force sensing without cameras or magnets
  • Normal cartridge: linear force response (R² = 0.999) from 104 mN to at least 5.8 N, 2.0% repeatability, 5.9% hysteresis, 6–10% taxel-to-taxel variation after normalization
  • Shear cartridge: summed three-axis force estimates reach R² = 0.96/0.96/0.92 in x/y/z across three indenter shapes and nine held-out sessions, with median shear-direction error of 4.8 degrees
  • Integrating LuxTac pressure readings into an Action Chunking Transformer policy substantially improves peg-in-hole success over a vision-only baseline

Highlights and analysis are generated automatically and may contain errors. Check the original source.